HPE OFFICECONNECT 1820 SERIES

Previous 1 / 1 Next

HPE OFFICECONNECT 1820 SERIES HPE | ARUBA SWITCH


 Smart-Managed, Fixed-Configuration Gigabit Ethernet Layer 2 Switches
  Description
  Introduction  1820 Series
  Features
  1. AC input 176Vac~264Vac
  2. Protections:SCP/OLP/OVP
  3. Batterylow protection/ Batter reverse polarity protection by fuse
  4. Constant current limiting for charging battery
  5. “0” switch time from the SMPS to Battery when AC fail
  6. 100% full load burn-in test
  7. 2 years warranty
  8. Suitable for CCTV, Door Control Access, Modem, Router, Switches and etc

-

MODEL

KHD-09005

OUTPUT

Ouput Number

V1

V2

DC Output

12.8V

13.8V

Rated Current

4A

0.5A£¨constant current£©

CurrentRange     Note 1

0.4~4A

/

Ripple and Noise  Note 2

0~50C

≤70mVp-p

/

-10~0C

≤120mVp-p

/

Voltage Accuracy

±1.0%

/

Line Regulation

±0.5%

/

Load Regulation

±3.0%

/

Voltage Adjustable Range

±30.0%

Set-up Time

£¼1S (230Vac input, Full load)

Hold up Time

£¾20mS(230Vac input, Full load)

Temperature Coefficient

±0.03%/¡æ

±1.0%/¡æ

Overshoot &Undershoot

<5.0%

INPUT

VoltageRange

176Vac~264Vac

FrequencyRange

47Hz-63Hz

Efficiency ( Typical)

>78%@230Vac

AC Current (max.)

2A

Inrush Current (Typical)

<40A@230Vac      Cold start

Leakage Current

Input—Output: ≤0.07mA   Input—PG: ≤3.5mA

PROTECTION

BatteryLow

9.9V±3%

Over Current

V1:105%-150% of rated current, hiccup mode,auto recovery

Over Voltage

V1: 105%-180% of rated voltage, auto recovery

Shorted Circuit

Long-time; auto recovery

ENVIRONMENT

Operating.Temp.& Hum.

-10¡æ~45¡æ;  20%~90%RH  No condensing

Storage Temp. & Hum.

-20¡æ~85¡æ;  10%~95%RH  No condensing

SAFETY &EMC  

(Note 3)

Safety Standards

GB4943-2001; EN60950-1£º2006

Withstand Voltage

Primary-Secondary:3.0KVac;≤10mA.Primary-PG:1.5KVac;≤10mA.Secondary-PG:0.5KVDC;≤10mA.

Isolation Resistance

≥100M ohms

OTHERS

MTBF (MIL-HDBK-217F)

More than 200,000Hrs (25¡æ, Full load)

Dimension  (L*W*H)

129×98×38mm

Cooling method

Cooling by free air convection

NOTE

1.All parameters NOT specially mentioned are measured at rated input, rated load and 25¡æ of ambient temperature.

2.Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor.

3.The SPS is considered a component which will be installed into final equipment. The equipment must be re-confirmed that it still meets EMC directives..